Connectivity

The OI Core Communication Driver must be installed prior to the installation of any OI Server communication driver.

Before installing the communication driver, please ensure the following:

  • Exit all Wonderware programs, including executable (.exe) files and services
  • Un-deploy the platforms where OI Core will be installed
  • Disconnect/close all 3rd party OPC clients of existing DAServers/OI Servers
  • Deactivate all DAServers/OI Servers

OI ABTCP (4.0)                                                                                               Download

Release Date : Dec 22, 2017
The following lists the supported hardware and firmware : 

  • PLC-5E (Ethernet based)
  • PLC-5 with Ethernet Communication Module
  • SLC505

OI ABCIP                                                                                                          Download

Release Date : Mar 8, 2017
OS and Product Compatibility: 
***Update 2019-Feb-07 Support for Firmware v32***
The controller families listed below with support for firmware 32 have the following constraints:
New data types are not supported. Such data types cannot be used as part of the communication within ABCIP
– Unsigned data types ( (USINT, UINT, UDINT, ULINT)
– 64-Bit data types (LREAL, ULINT)

Hardware Compatibility:

ControlLogix                                              CompactLogix
– L5x/L6x: up to Firmware 20                   – 1768/9-Lx: up to Firmware 20
– L7x: up to Firmware 31                           – 1769-LxxER*: up to Firmware 31
– L8xE: up to Firmware 32                         – 5069-LxxxER*: up to Firmware 32

GuardLogix                                                 Compact GuardLogix
– L6xS: up to Firmware 20                        – 1768-LxxS: up to Firmware 20
– L7xS: up to Firmware 31                        – 1769-LxxER*S: up to Firmware 31
– L8xES: up to Firmware 32                      – 5069-LxxxER*S2: up to Firmware 32

FlexLogix                                                    SoftLogix
– Lxx: up to Firmware 16                          – Lx: up to Firmware 23

MicroLogix                                                  PLC-5
– 1100: up to Firmware 16                       SLC500
– 1200/1500: up to Firmware 14
– 1400:up to Firmware 21

OI TWINCAT                                                                                                    Download

Release Date : Jul 6, 2016
The OI Server uses the ADS Library for communication and should support any TCP/IP Ethernet Beckhoff device compatible with the ADS Library version you install. The following devices were used in the conformance tests:

  • ADS Library: TC1000:TC3
  • Beckhoff TwinCAT PLC/IO on Windows XP/7/8
  • CX1000 and CX1020 with Windows Embedded Compact 5.0 and 6.0
  • PLC BC9000, BX9000 and CP66xx with Windows Embedded Compact 5.0 for ARMV4i processor
  • The TC1000:TC3 Library should also be compatible with CX1010, CX1020, CX1030, CX2000, CX5000, CX5100, CX8000, and CX9000 and any other device hosting the TwinCAT runtime 2 and 3.

If you are unsure if your specific device is supported, please contact your Beckhoff support and confirm your device compatibility with the ADS Library.

OI GESRTP                                                                                                       Download

Release Date : Aug 24, 2015

Hardware Compatibility:

  • Series 90-30
  • Series 90-70
  • Versamax
  • Versamax Micro
  • Versamax Nano
  • PACSystems (RX3i, RX7i)

OI MELSEC                                                                                                       Download

Release Date : Jul 6, 2016
The following Mitsubishi Controller families are supported:

  • MELSEC-Q
  • MELSEC-QnA
  • MELSEC-L

NOT SUPPORTED WITH THIS VERSION

  • MELSEC-iQ-R
  • MELSEC-iQ-F
  • MELSEC-F
  • MELSEC-QS/WS

OI OMRONFINS                                                                                               Download

Release Date : Jul 6, 2016

Supports the Omron PLCs on a FINS network:

  • CJ1 Series
  • CJ2 Series
  • CS1 Series
  • CP1 Series
  • CV Series
  • CVM1, and CVM1D Series

The following platforms support the FINS protocol, but were not tested. As such compatibility cannot be guaranteed.

  • C200 Series
  • NJ Series
  • NX Series
  • NSJ Series

OI Gateway (6.0)                                                                                              Download

Release Date : Jan 12, 2019
Replaces the FS Gateway. Supports connectivity via :

  • SuiteLink
  • DDE
  • OPC-UAClient
  • ArchestraMessageExchange
  • InTouch
  • MQTTSubscriber/Publisher(IoT connectivity)

OI MBTCP                                                                                                          Download

Release Date : Aug 24, 2015
Hardware Compatibility:

  • TSX Quantum
  • TSX Momentum
  • TSX Premium
  • Generic Modbus TCP
  • Compact 984 (thru Modbus Bridge)
  • Modicon Micro (thru Modbus Bridge)
  • Generic Modbus Serial (thru Modbus Bridge)”

 

OI SoMachine                                                                                                    Download

Release Date : Dec 22, 2017
For Schneider Electric devices that support the Codesys protocol:

Logic Controllers:
– Modicon M241 PLC
– Modicon M251 PLC

Motion Controllers:
PacDrive 3 LMC Eco / Pro / Pro 2

OI SIDirect (5.0)                                                                                               Download

Release Date : May 17, 2018
The following lists the supported hardware and firmware with the SIDirect OI Server.

S7-200
– Not Supported

S7-300
– Polling / Cyclic mode Supported
*** Supported up to firmware version 3.3.14***
– CPU 312 [ C ]
– CPU 313-2 DP [ C/PtP ]
– CPU 314-2 PN/DP [ C/PtP ]
– CPU 315-2 PN/DP [ F ]
– CPU 317-2 PN/DP [ F ]
– CPU 319-3 PN/DP [ F ]

S7-400 (S7-400H)
– Polling / Cyclic mode Supported
*** Supported up to firmware version 7.0.0***
– CPU 412 PN [ H ]
– CPU 414 PN/DP [ F/H ]
– CPU 416 PN/DP [ F/H ]
– CPU 417 [ H ]

S7-1200 Basic Controllers
– Polling / Cyclic / Legacy / Symbolic mode Supported
*** Supported up to firmware version 4.2.0***
– CPU 1211 [ C ]
– CPU 1212 [ C/FC ]
– CPU 1214 [ C/FC ]
– CPU 1215 [ C/FC ]
– CPU 1217 [ C ]

S7-1500 Software Controllers
– Polling / Cyclic / Legacy / Symbolic mode Supported
*** Supported up to firmware version 2.5.0 ***
– CPU 1511-1 PN  [ C/F/T/TF ]
– CPU 1512-1 PN  [ C ]
– CPU 1513-1 PN  [ F/R ]
– CPU 1515-2 PN  [ F/T/TF ]
– CPU 1516-3 PN/DP  [ F/T/TF ]
– CPU 1517-3 PN/DP  [ F/T/H/TF ]
– CPU 1518-4 PN/DP  [ F/ODK/MFP ]

SIMATIC ET 200 Distributed Controllers
– Not Supported

SIMATIC S7-PLCSIM Advanced v2.0
– Not Supported

OI ADPRO                                                                                                         Download

Release Date : Jul 6, 2016
Support Automation Direct Productivity Series Controllers 2000 & 3000

 

OI DOMOR                                                                                                         Download

Release Date : Jul 6, 2016
Supports Automation Direct Controllers Do-More H2 Series

 

OI KOYO                                                                                                            Download

Release Date : Jul 29, 2016

DirectLOGIC DL05 and DL06 PLCs, with H0-ECOM or H0-ECOM100 Ethernet module
DirectLOGIC DL205 Family (DL240/DL250-1 and DL260 CPUs), with H2-ECOM or H2-ECOM100 Ethernet module
Any device that is compatible with AutomationDirect’s DirectNet protocol

OI BACLITE                                                                                                      Download

Release Date : Jul 6, 2016

Controllers that support the BacNET protocol

Note: Change of Value (COV) is not supported

OI CODESYS                                                                                                   Download

Release Date : Jul 6, 2016

Codesys based protocols based on CODESYS version 2.x, 3.x.

The following were qualified internally, but the driver can still work with suppliers that use the CODESYS

Bosch Rexroth
– L40 and L65

CODESYS
– SP WIN V3.5.1 Control
– SP PLCWinNT V2.4.4.0

EATON
– XC-CPU202 CODESYS V3.5

Schneider Electric
– 241/M251

WAGO
– Wago CPU 750-841

OI SNMPDRV                                                                                                   Download

Release Date : Dec 22, 2017

  • Support SNMP v3
  • Support SNMP v2c
  • Support SNMP v1
  • Table Suppport
  • GET and SET operations
  • Receive Traps

OI TI500                                                                                                            Download

Release Date : Nov 16, 2017

  • Support for UDP/IP and improved performance for TCP/IP.
  • Support for Drum Memory.
  • Support for Loop and PID Variables.
  • Improved OI Server Reliability and Performance.
  • Support for String

Hardware:
– Supports the Control Technology Inc.- CTI2500(replacing the TI500’s series)
– Supports the controllers- TI545 / 565 / 575
– Supports Serial and Ethernet connectivity

OI WEBSVC                                                                                                       Download

Release Date : Nov 16, 2017

Supports communications with client web services over an HTTP/S network using the following communication protocols (on the internet or intranet):

  • Simple Object Access Protocol (SOAP)
  • Representational State Transfer (REST)
  • Supports automatic or triggered based polling for Data requests.
  • Payload Support:
    – SOAP: XML format only
    – REST: XML or JSON formats
  • REST specific functionality:
    – Use of parameters as variables
    – Unique identifier for array based result sets
    – Export of result set to device Items (and aliasing support)